Vermont Casting 2490 Resolute Acclaim Clearance Chart, Unprotected Surface, Protected Surface

Models: 2490

1 32
Download 32 pages 15.33 Kb
Page 12
Image 12
Resolute Acclaim Clearance Chart

Resolute Acclaim Woodburning Stove

Resolute Acclaim Clearance Chart

 

 

Unprotected Surface

 

Protected Surface

 

 

 

Parallel Installation

 

Corner

 

Parallel Installation

 

Corner

 

 

 

 

Installation

 

Installation

 

 

 

 

 

 

 

 

 

 

Stove Clearance

 

Side

Rear

 

Corner

 

Side

Rear

 

Corner

 

No heat shields

 

(A) 15”

(B) 24”

 

(C) 15”

 

(D) 8”

(E) 13”

 

(F) 8”

 

 

(380 mm)

(610 mm)

 

(380 mm)

 

(203 mm)

(330 mm)

 

(203 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top exit, rear heat

 

(G) 15”

(H) 24”

 

(I) 15”

 

(J) 8”

(K) 13”

 

(L) 8”

 

shield only 1

 

 

 

 

 

 

(380 mm)

(610 mm)

 

(380 mm)

 

(203 mm)

(330 mm)

 

(203 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear exit, rear heat

 

(M) 15”

(N) 10”

 

N/A

 

(O) 8”

(P) 7”

 

N/A

 

shield only

 

(38mm)

(254 mm)

 

 

 

(203 mm)

(180 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top exit, rear h.s.,

 

(Q) 15”

(R) 15”

 

(S) 15”

 

(T) 8”

(U) 9”

 

(V) 8”

 

single-wall connector,

 

(380 mm)

(380 mm)

 

380 mm)

 

(203 mm)

(23mm)

 

(203 mm)

 

connector shields 1,2

 

 

 

 

 

 

 

 

 

 

 

Top exit, rear h.s.,

 

(Q) 15”

(R) 17”

 

(S) 15”

 

 

*

 

 

 

double-wall connec-

 

(380 mm)

(432 mm)

 

(380 mm)

 

 

 

 

 

 

tor1,3

 

 

 

 

 

 

 

 

 

 

 

Chimney Connector

 

 

 

 

 

 

 

 

 

 

Clearance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Heat Shields

 

23” (580 mm)

 

 

12” (305 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chimney connector

 

 

 

 

 

 

 

 

 

 

heat shields2

 

14” (360 mm)

 

 

8” (203 mm)

 

 

 

 

 

 

 

 

 

 

 

 

Double-wall connector3

 

16” (410 mm)

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front Clearance

 

 

 

 

 

 

 

 

 

 

to Combustibles**

 

 

All Installations

48” (1220 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Clearances with double-wall connectors and protected surfaces have not been tested for the Resolute Ac- claim.

**A distance of 48” must be maintained between the stove and moveable combustible items such as drying clothes, furniture, firewood, etc.

1When a rear heat shield is installed on a top exit stove, the shield insert must be attached to the shield so the area behind the flue collar on the stove is protected.

2Chimney connector heat shields must extend exactly 28” (710 mm) above the flue collar of the stove. No shielding can be used on the connector above 28” (710 mm). The unshielded chimney connector above the 28” (710 mm) point will be 14” (360mm) from an unprotected wall or 8” (203 mm) from a protected wall.

3In top exit installations, this clearance requires the use of the rear stove heat shield with the shield insert installed.

12

2000893

Page 12
Image 12
Vermont Casting 2490 Resolute Acclaim Clearance Chart, Unprotected Surface, Protected Surface, 2000893