•Close the damper and thermostat lever.

Encore Woodburning Stove

If you do experience a chimney fire, act promptly to:

Close the damper and thermostat lever.

Get everyone out of the house.

Call the Fire Department.

You should inspect the system every two weeks during the heating season as part of a regular maintenance schedule. To inspect the chimney, let the stove cool completely. Then, using a strong light, sight up through the flue collar into the chimney flue. If it is not possible to inspect the flue system in this fashion, the stove must be disconnected to provide better viewing access.

Clean the chimney using a brush the same size and shape as the flue liner. Flexible fiberglass rods are used to run the brush up and down the liner, causing any deposits to fall to the bottom of the chimney where they can be removed through the clean-out door.

Clean the chimney connector by disconnecting the sec- tions, taking them outside, and removing any deposits with a stiff wire brush. Reinstall the connector sections after cleaning, being sure to secure the joints between individual sections with sheet metal screws.

If you cannot inspect or clean the chimney yourself, contact your local Vermont Castings’ Dealer or a profes- sional chimney sweep.

Annual Maintenance

Every Spring, at the end of the heating season, perform a thorough cleaning, inspection and repair. The stove and chimney system should be inspected and main- tained by a qualified engineer and include the following:

Thoroughly clean the chimney and chimney connec- tor.

Inspect the chimney for damage and deterioration. Replace weak sections of prefabricated chimney. Have a mason make repairs to a masonry chimney.

Inspect the chimney connector and replace any damaged sections.

Check gasketing for wear or compression, and re- place if necessary.

Inspect and clean the catalytic element, and vacuum out the ash at the bottom of the back plate after re- moving the lower fireback. Lightly clean the refracto- ry assembly that houses the element but be careful not to damage the refractory material, which is very fragile.

Check door and damper handles for tightness. Ad- just if needed.

Check heat shield screws. Tighten as necessary.

Clean dust from the inner sides of bottom, rear and connector heat shields.

Remove ashes from the ash pan and replace with moisture absorbing material (such as cat litter) to keep the stove interior dry.

Touch up the paint on black stoves.