Encore Woodburning Stove
•The fireplace damper must be sealed to prevent room air from escaping up the flue. However, it must be possible to
Chimney | * |
Connector Shields | |
| |
| * |
* Check | Mantel |
These Clear- |
|
ances |
|
| Seal this off |
ST244 |
|
Fig. 7 In this installation, the chimney connector is attached to the chimney above the fireplace opening.
Through the Fireplace
If your fireplace opening height is at least 675 mm (26¹⁄₂"), you may install an Encore through the opening using a “positive connection” kit, available from your local dealer. These positive connection kits ensure a tight fit between the stove flue collar and the chimney flue. (Fig. 8)
Fireplace installations, whether connected to the flue above or through the fireplace opening, have special clearance requirements to adjacent trim and the mantel. You’ll find the required safe clearances for Encore fire- place installations on Page 11.
Floor protection requirements also apply to fireplace installations. This information is on Page 9.
Wall Pass-Throughs
Whenever possible, design your installation so the con- nector does not pass through a combustible wall. If you are considering a wall
Also, check with the chimney connector manufacturer for any specific requirements.
Accessories are available for use as wall pass- throughs. If using one of these, make sure it has been tested and listed for use as a wall
Flexible Connector
Mantel Shield
Fireplace Adapter
Kit “Positive Con- nection”
ST245
Fig. 8 In this installation, the chimney connector enters the firepalce opening and then connects to the chimney.
Figure 9 shows one method of passing a connector through a wall. All combustible material in the wall is cut away to provide the required 457 mm (18”) clearance for the connector. The resulting space must remain empty. A
Your local dealer or your local building inspector can provide details for other approved methods of passing a chimney connector through a combustible wall in your area.
DO NOT CONNECT AN ENCORE TO ANY AIR DIS- TRIBUTION DUCT OR SYSTEM.
457 mm (18”) clear space all around the pipe
ST494
Fig. 9 An approved wall
8 | 30003842 |