Vermont Casting 2550CE Masonry Chimney, Freestanding Installations, Fireplace Installations

Models: 2550CE

1 32
Download 32 pages 52.11 Kb
Page 7
Image 7
Masonry Chimney

Encore Woodburning Stove

Chimney Freestanding Installations Flue

Elbow

Flue Liner

 

Thimble Sleeve

Chimney Connector Fireplace Installations

Flue

Slip Pipe

Standard Above the Fireplace Connector Manual background

Oval to

Round Adapter Manual background

Thimble

Keep sleeve end flush with flue tile

ST243

Manual background Flue Collar

ST492

Fig. 5 Chimney connection in a freestanding masonry instal- lation.

Securing the Single-wall Connector to a

Masonry Chimney

Both freestanding masonry chimneys and fireplace masonry chimneys may be used for your installation.

Freestanding Installations

If the chimney connector must pass through a combus- tible wall to reach the chimney, follow the recommenda- tions in the Wall Pass-Through section that follows.

The opening through the chimney wall to the flue (the “breech”) must be lined with either a ceramic or metal cylinder, called the “thimble”, which is cemented securely in place. Most chimney breeches incorporate thimbles, but the fit must be snug and the joint between the thimble and the chimney wall must be cemented firmly.

A special piece called the “thimble sleeve,” slightly smaller in diameter than standard connectors and most thimbles, will facilitate the removal of the chimney connector system for inspection and cleaning. Thimble sleeves should be available from your local dealer.

To install a thimble sleeve, slide it into the breech until it is flush with the inner flue wall. Do not extend it into the actual flue passage, as this could interfere with the draft.

Fig. 6 The thimble, made of either ceramic or metal, must be cemented securely in place.

The thimble sleeve should protrude 1-2” (25-50mm) into the room. (Fig. 6) Use furnace cement and thin gasket- ing to seal the sleeve in place in the thimble. Secure the chimney connector to the outer end of the sleeve with sheet metal screws.

Without a thimble, a suitable length of chimney con- nector can be extended through the breech to the inner face of the flue liner, and cemented securely in place. Additional pieces of connector are then attached with sheet metal screws.

Fireplace Installations

The chimney connector may be connected to the chimney above the fireplace opening or through the fireplace.

Above the Fireplace

The Encore may be connected to a chimney above a fireplace opening. (Fig. 7) In such installations, the stove is positioned on the hearth in front of the fireplace and the chimney connector rises from the stove top and then angles ninety degrees back into the chimney. The chimney liner should extend to the point at which the chimney connector enters the chimney.

If the chimney connector from your installation enters the chimney above a fireplace, follow all the guidelines mentioned above for freestanding installations. In addi- tion, give special consideration to the following points:

Check the clearance between the stove and the chimney connector, and any combustible trim or the mantel. Use the necessary combination of mantel, trim, and connector heat shields to achieve the required clearances.

Check the clearance between the chimney con- nector and the ceiling. If no heat shields are used, the clearance should be at least 610 mm (24”). To find out how much this clearance may be reduced with heat shields, refer to the clearance chart on Page 12.

30003842

7

Page 7
Image 7
Vermont Casting 2550CE Masonry Chimney, Freestanding Installations, Fireplace Installations, Above the Fireplace, 30003842