Vermont Casting 2995, 2950, 2951, 2998 Through Side Wall Vent Termination Below Grade, 20003457

Models: 2950 2995 2998 2996 2997 2951

1 46
Download 46 pages 17.56 Kb
Page 17
Image 17
Vent Opening - Combustible Wall

Vermont Castings Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters

Sealant

Phillips

Screws

ST396

Fig. 23 Apply sealant to the starter pipe, and fasten to stove with Phillips screws.

2.Locate the vent opening on the wall. Refer to Figures 24, 25 & 26 to determine the top of the opening centerline. It may be necessary to first position the stove and measure to find the hole location. Depending on whether the wall is made of combustible materials, cut the opening to the size shown in Figure 24. Combustible wall openings must be framed as shown in Figure 24

Vent Opening - Combustible Wall

9³⁄₈"

(240mm)

10³⁄₈"

(265mm)

Framing Detail

Vent Opening -Noncombustible Wall

 

7¹⁄₂" Dia.

 

 

(190mm)

 

 

 

VO584-100

Fig. 24

Locate vent opening.

 

9³⁄₈” W x 10³⁄₈” H

Firestop

Wall Opening

Wall Sleeve -

Ventilated Wall Plate -

Open End Down

Seal Around

Finishing Collar

 

 

 

27³⁄₈"

 

 

(695mm)

 

 

to Top of

 

Seal

Opening

 

 

 

Around

 

Terminal

 

ST400

 

 

Fig. 25 SDVR with Rear Vent Kit 7TFSRSK installation.

9³⁄₈” W x 10³⁄₈” H

Firestop

Wall Opening

Ventilated Wall Plate -

Wall Sleeve -

Open End Down

Seal Around

Finishing Collar

 

25³⁄₄"

 

(654mm)

 

to Top of

 

Opening

 

Seal

 

Around

 

Terminal

 

ST400

 

Fig. 26 PDV20 with Rear Vent Kit 7TFSRSK installation.

3.Measure the wall thickness and cut the wall sleeve sections to proper length (MAXIMUM 12”). Assemble the sleeve with the #8 sheet metal screws supplied. Attach the firestop plate to the sleeve end with the holes. (Fig. 32) NOTE: The wall sleeve is required in combustible walls only.

4.Install the Wall Firestop/Sleeve assembly into the wall cutout and fasten the firestop to the wall cutout framing members. (Figs. 25, 26)

5.Measure, and cut if necessary, the appropriate length of pipe section needed to make the connec- tion through the wall.

6.Slip the wall plate and trim collar over the interior end of the horizontal pipe and install into the wall sleeve. Seal the joint inside the wall plate if needed to keep cold air from being drawn into the home.

7.Connect the pipe to the inner collar. Fasten the wall plate to the pipe with three sheet metal screws. Slide the trim collar up against the wall plate to cover the screws. (Figs. 25, 26)

8.Install the vent terminal. (Figs. 25 & 26) Guide the inner and outer vent termination collars into the adjacent pipes. Double check that the vent pipes overlap the collars by 2”. Fasten the termination to the wall with the screws provided, and caulk the joint with weatherproof sealant.

Through Side Wall /

Vent Termination Below Grade

Refer to Figures 27 & 28 for minimum centerline of wall opening.

1.Attach Inner Starter Pipe, (found in with the logset), to the stove.

• Run a bead of sealant beneath the pipe bead and attach to the stove using three 1/4-20 x 3/8” phillips screws provided in the parts bag. (Fig. 29)

20003457