Vermont Casting 3031, 3033 Install Optional Fan Kit, Vermont Castings UVS27 Vent-FreeGas Heater

Models: 3030 3031 3032 3033

1 26
Download 26 pages 62.24 Kb
Page 10
Image 10
Install Optional Fan Kit

Vermont Castings UVS27 Vent-Free Gas Heater

Right

Side

Wingbolt

ST105

Fig. Secure right side to the back panel.

5.Lift the firebox assembly as a unit and slide it back to position it within the shell. The base of the firebox should rest on the side support shelves as in Figures 7 and 9. The side plates interlock with the firebox by use of a pair of steel tabs that engage with the ribs on the base of the firebox. (Fig. 9) Properly posi- tioned, the firebox will be level and locked in place. If not, adjust the levelling screws as required to keep the entire assembly level.

Steel Tab

Manual background Side Plate

Screw & Washer

Back Panel

Side

Plate Manual background

Support Shelf

ST106

ST125

Fig. 9 Install the firebox assembly,. Be sure steel tabs engage ribs on base of firebox.

Install Optional Fan Kit

1.

Attach the fan to the firebox by engaging the upper

 

flange of the fan skirt under the lower edge of the

 

shroud and secure the skirt with the four screws and

 

one star washer provided. (Fig. 10, 11)

2.

Feed the snapstat wire lead up between the inner

 

and outer rear shroud panels and secure the

 

snapstat to the upper right side of the inner shroud.

 

(Fig. 12)

Fig. 7 The sides must be at right angles to the back panel in order for the firebox to fit properly.

4.Connect the gas supply line to the burner control valve before you install the firebox. This may be a flexible line, (not supplied), or hard plumbing.

1/2” Gas Supply

1/2” NPT x 1/2” Flare Shutoff

Valve

3/8” Flex Line

(from Valve)

FP297a

Fig. 8 Typical gas supply installation.

3.

Secure the snapstat wire harness to the shroud

 

panel using the wire tie provided.

4.

Route the rheostat control switch and wire forward

 

under the stove. Use the wire tie to secure the fan

 

and rheostat wire harnesses together to the tubing

 

under the bottom heat shield.

5.

Install the rheostat onto the bracket to the left of the

 

valve. (Fig. 13)

10

20005004

Page 10
Image 10
Vermont Casting 3031, 3033, 3030, 3032 manual Install Optional Fan Kit, Vermont Castings UVS27 Vent-FreeGas Heater, 20005004