Vermont Casting 43LDVT Troubleshooting the Gas Control System, Normal Operation, 10007852

Models: 3LDVT 36LDVT 39LDVT 43LDVT

1 40
Download 40 pages 2.33 Kb
Page 29
Image 29
Troubleshooting the Gas Control System

LDVT Series Direct Vent GaS Fireplace

Troubleshooting the Gas Control System

SIT 822 Valve with Synetek Electronic Control

Operating Diagram

Normal Operation

ON/OFF Switch Closed?

YES

Safe Start Check On?

YES

0 Sec Purge

NO

Abnormal Operation

5 sec Inter-Trial Delay

LED: Steady Flash?

Lockout: Flame detected out of sequence Reset by interrupting ON/OFF switch or power for 10 sec

LED: 5 Flashes?

Normal Operation Reverse power cord polarity

Ignition Trial: 30 sec Spark ON Pilot Valve ON. Has Flame been Detected within 30 sec?

Spark Off. Main Valve ON.

Pilot Flame Continuously

Monitored

Pilot Flame Sense OK?

ON/OFF Switch Opened?

YES

Pilot and Main Valve OFF?

YES

NO

NO

LED: 2 Flashes?

Reset by interrupting ON/OFF switch for power for 10 sec

YES

Pilot, Valve OFF, Spark OFF

Have three ignition trials been completed? NO

LED: 3 Flashes?

Lockout: Flame Loss

Reset by interrupting ON/OFF switch or power for 10 sec

YES

Main Valve OFF, Spark ON

 

 

Has flame been detected within 30 sec?

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

Have three pilot flame losses been

 

YES

 

 

detected?

 

 

 

 

 

 

 

 

 

 

 

0 sec Post Purge?

Heating Cycle Complete LED:

OFF

10007852

29

Page 29
Image 29
Vermont Casting 3LDVT Troubleshooting the Gas Control System, LDVT Series Direct Vent GaS Fireplace, Normal Operation