LDVT Series Direct Vent Gas Fireplace
43LDVT
1. | Place rear log (BD15) on rear bracket |
| (ensure log is centered and seated |
| properly to the log support). |
2. | Place front left log (BD16). Use log’s |
| bottom notch to locate it onto the front |
| support and just rest on top of the |
| burner housing assembly. |
3. | Place front right log (BD17). Use log’s |
| bottom notch to locate it onto the front |
| support and just rest on top of the |
| burner housing assembly. |
4. | Place ember material on top of burner. |
5. | Scatter the ember material over the |
| tiles on the front area of the burner |
| housing. (Fig. 40) Do not pack the |
| ember material. Separate it when |
Rear (BD15)
Front
Left (BD16)
Top Center (BBD18)
Front Right (BD17)
unpacked and keep it in a fluffy and |
loose condition for a more realistic |
ember effect. |
6. Place front center log (B138) on top of |
the two small shelves at the front log |
support, and between the left and right |
logs. |
| Lava |
| Rock |
Lava Rock | Ember Material |
| |
Front Center |
|
(B138) | LG434 |
Fig. 40 Correct log placement for 43LDVT.
7.Place top center log (BD18) on top of
the rear log using the hole locator under the log and on top of front right log.
8.Scatter lava rock material round the firebox base.
Flame & Temperature Adjustment
RN/RP & EN/EP Models
For units equipped with ‘HI/LO’ valves the flame adjustment is accomplished by rotating the ‘HI/LO’ adjustments knob located near the center of the gas control valve. (Fig.
Turn |
|
|
|
counterclockwise | �� | �� | Turn clockwise |
to decrease |
| to increase | |
|
| ||
flame height |
|
| flame height |
| |||
Fig. 41 Flame adjustment knob for Honeywell valve. | |||
|
|
|
|
Turn |
|
| Turn clockwise |
counterclockwise |
| H | |
|
| I |
|
to increase | L |
| to decrease |
O |
| flame height | |
flame height |
|
| |
|
|
|
|
Fig. 42 Flame adjustment knob for SIT valve.
Do not place any of the lava rock material on the burner housing assembly.
Flame Characteristics
It is important to periodically perform a visual check of the pilot and burner flames. Compare them to Figures 43 and 44.
If the flame patterns appear abnormal contact a qualified service provider for service and adjustment.
SIT RN/RP
SIT EN/EP
FP1541
Fig. 43 Correct pilot flame appearance.
24 | 10007852 |