DV Power Vent System
Wiring Diagram (Synetek Ignition Module)
CFM 10007939 |
|
|
|
| Synetek Ignition Module |
Thermostat (W) Key Pilot Valve Hot Main Valve Hot Pilot / Main Valve Rtn. |
| LED 1/4” Male Tab |
| Chasis / Burner Ground | |
24Vac Hot (R) |
| 120Vac Hot 120Vac Rtn Fan Rtn Fan Hot Key Flame Sense | |||
|
|
FIELD SUPPLIED & INSTALLED WIRES
WIRE SPEC.: 18 AWS SOLID, LOW VOLTAGE
MINIMUM INSULATION 2/64"
TO WALL THERMOSTAT OR ON/OFF SWITCH | Fireplace |
Main Valve | Pilot Valve |
J2 | J1 |
Ignitor
Burner Ground
Sensor | L1 120/220 Vac (Hot) L2 120/220 Vac (Rtn) | Fireplace |
Power Vent Kit | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
WHITE | BUSHING |
GREEN
RTN
BLACK
WHITE
HOT
Power Vent Kit
Hose
LED Codes |
|
ON | Normal operation |
2 Flash | Ignition trial lockout |
3 Flash | Flame loss lockout |
5 Flash | 120V AC reversed polarity |
| or board not sensing ground |
Steady Flash | Flame detected out of al- |
| lowed sequence or internal |
| fault, hardware error |
|
|
YELLOW
BLUE
NO NC COM
14 | 10003262 |