Vermont Casting Chateau, Termination Clearances, Application, DVT38N, DVT38P, DVT44N, DVT44P

Models: DVT38

1 40
Download 40 pages 28.48 Kb
Page 11
Image 11
Termination Clearances

Chateau™

Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.

Inside Corner

 

Outside Corner

 

 

A =

 

 

B =

A

 

 

Combustible

Combustible

 

 

6"(152mm)

 

6"(152mm)

 

V

Noncombustible

 

Noncombustible

2"(50mm)

 

 

V

2"(50mm)

 

B

 

Balcony -

 

Balcony -

 

 

with no side wall

 

with perpendicular side wall

G

H

 

 

 

V

 

V

G =

Combustible &

J

 

Noncombustible

 

Combustible &

 

Noncombustible

H = 24"(610mm)

 

12"(305mm)

J = 20"(508mm)

 

 

 

Recessed Location

Application D Item

CDVT38NDVT38PC

DVT44N E DVT44P

V

C = Maximum depth of 48" (1219mm) for recessed location.

D = Minimum width for back wall of a recessed location. Combustible 38"(965mm) Noncombustible 24"(610mm)

E = Clearance from corner in recessed location. Combustible 6"(152mm) Noncombustible 2"(50mm)

584-15

Fig. 13 Termination clearances.

Quick Reference for Fresh Air Restrictor Plate / Flue Baffle

Application

Item

DVT38N

DVT38P

DVT44N

 

DVT44P

 

SK8DVSK

Flue Restrictor Plate

3”

None

None

 

4¹⁄

 

Fresh Air Restrictor Plate

None

None

None

 

#1

Vertical Less than 12’

Flue Restrictor Plate

None

None

None

 

None

 

Fresh Air Restrictor Plate

None

None

None

 

None

Vertical 12’ to 20’

Flue Restrictor Plate

4¹⁄

4¹⁄

4¹⁄

 

4¹⁄

 

Fresh Air Restrictor Plate

#3

#3

#3

 

#3

Vertical 20’ to 30’

Flue Restrictor Plate

4¹⁄

4¹⁄

4¹⁄

 

4¹⁄

 

Fresh Air Restrictor Plate

#2

#2

#2

 

#2

Vertical 30’ to 40’

Flue Restrictor Plate

4¹⁄

4¹⁄

4¹⁄

 

4¹⁄

 

Fresh Air Restrictor Plate

#1

#1

#1

 

#1

20006081

11

Page 11
Image 11
Vermont Casting installation instructions Chateau, Termination Clearances, Application, DVT38N, DVT38P, DVT44N, DVT44P