Vermont Casting DVT38 General Venting, Chateau, Location of Vent Termination

Models: DVT38

1 40
Download 40 pages 28.48 Kb
Page 9
Image 9
General Venting

PILOT

 

 

HONEYWELL IGNITION MODULE

 

MV

MV/VP PV

24V

24V

SENSE SPARK

GRD

1

2

3

5

6

8

9

Chateau™

General Venting

Your fireplace is approved to be vented either through the side wall, or vertical through the roof.

Only Vermont Castings, Majestic Products venting components specifically approved and labelled for this fireplace may be used.

Venting terminals shall not be recessed into a wall or siding.

Horizontal venting must be installed on a level plane without an inclining or declining slope.

BLACK

WHITE

To Receptacle

Supplied

in Valve Box

120 VAC RTN Location of Vent Termination

WHITE

BLACK

GREEN

120 VAC HOT

WHITE

HI

 

NOVA SIT 822 VALVE

BLACK

24 VAC HOT

BLACK

 

BLACK

 

WHITE

WHITE

 

 

WALL SWITCH

24 VAC RET

 

There must not be any obstruction such as bushes, gar- den sheds, fences, decks or utility buildings within 24” (610mm) from the front of the termination hood.

Do not locate termination hood where excessive snow or ice build up may occur. Be sure to check vent termi- nation area after snow falls, and clear to prevent ac- cidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

Location of Vent Termination

It is imperative the vent termination be located observ- ing the minimum clearances as shown on following page.

FP1367

40VA TRANSFORMER

 

BLACK

WHITE

 

Fig. 11 Honeywell ignition module.

20006081

9

Page 9
Image 9
Vermont Casting DVT38 installation instructions General Venting, Chateau, Location of Vent Termination