PILOT
|
| HONEYWELL IGNITION MODULE |
| |||
MV | MV/VP PV | 24V | 24V | SENSE SPARK | ||
GRD | ||||||
1 | 2 | 3 | 5 | 6 | 8 | 9 |
Chateau™
General Venting
Your fireplace is approved to be vented either through the side wall, or vertical through the roof.
•Only Vermont Castings, Majestic Products venting components specifically approved and labelled for this fireplace may be used.
•Venting terminals shall not be recessed into a wall or siding.
•Horizontal venting must be installed on a level plane without an inclining or declining slope.
BLACK
WHITE
To Receptacle
Supplied
in Valve Box
120 VAC RTN
WHITE
BLACK
GREEN
120 VAC HOT
WHITE
HI |
|
NOVA SIT 822 VALVE | BLACK |
24 VAC HOT | BLACK |
| |
BLACK |
|
WHITE | WHITE |
| |
| WALL SWITCH |
24 VAC RET |
|
There must not be any obstruction such as bushes, gar- den sheds, fences, decks or utility buildings within 24” (610mm) from the front of the termination hood.
Do not locate termination hood where excessive snow or ice build up may occur. Be sure to check vent termi- nation area after snow falls, and clear to prevent ac- cidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.
Location of Vent Termination
It is imperative the vent termination be located observ- ing the minimum clearances as shown on following page.
FP1367 | 40VA TRANSFORMER |
| |
BLACK | WHITE | ||
|
Fig. 11 Honeywell ignition module.
20006081 | 9 |