Log Identification Chart
Location | H33BDVRRN/P |
Front Right | BA9 |
Rear Left | BA7 |
Rear Fr Rt | BA8 |
|
|
Refer to Figure 37
1.Remove the top louvre assembly.
2.Remove the window frame assembly.
3.Fit the rear front right log (BA8) onto the rear log support.
Ensure the rear right end of the log is located against the bracket bending up on the right side of the support.
4.Fit the rear left log (BA7) onto the rear support. Ensure the rear right end of the log is located against bracket bending up on the right side of the support.
5.Place the right rear log (BA9) in position by resting the hole under the center of this log located over the knob on the branch of the rear front right log, and the front end of this log will also set against the back wall of the deflector. (Fig. 37)
6.Scatter the ember material over the front area of the burner housing assembly (Refer to Figure 38 for details). Do not pack this material tightly, separate it when unpacked and keep it in a loose condition.
7.Scatter the lava rock material around the firebox base.
Do not place any of the lava rock material on the burner housing.
BA7 | BA8 |
BA9
Embers
LG259
Fig. 37 H33BDVRRN/P log placement.
Pyromaster© H33BDVRRN/P
Flame & Temperature Adjustment
For units equipped with ‘HI/LO’ valves the flame adjustment is accomplished by rotating the ‘HI/LO’ adjustment knob located near the center of the gas control valve. (Fig. 38)
Turn |
|
|
|
counterclockwise | LO | HI | Turn clockwise |
to decrease |
| to increase | |
|
| ||
flame height |
|
| flame height |
|
|
| HV102 |
|
|
|
|
Fig. 38 Flame adjustment knob for Honeywell valve.
Flame Characteristics
It is important to periodically perform a visual check of the pilot and burner flames. Compare them to the figures below. (Figs.
If the flame patterns appear abnormal contact a qualified service provider for service and adjustment.
3/8” - 1/2”
Fig. 39 Correct pilot flame appearance.
LG260
Fig. 40 Correct flame appearance.
10004798 | 21 |