Pyromaster© H33BDVRRN/P
Wiring Instructions
The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electric Code.
For USA installations follow the local codes and the national electrical code ANSI/NFPA No. 70.
Should this fan require servicing or repair the power supply must be disconnected. For rewiring of any replacement parts refer to Figure 43.
Any electrical rewiring of this fan must be done by a licensed electrician.
Fan |
Temperature |
Sensor |
Speed Control |
Black |
White |
Ground |
FP1025 |
Fig. 43 FK24 fan wiring. |
EB-1 Electrical Box
The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code.
For USA installations follow local codes and the national electrical code ANSI/ NFPA No. 70.
3.Remove the plug socket assembly from the
4.Feed the supply line in through the
5.Connect the black wire of the power supply line to the brass screw (polarized) of the socket assembly.
6.Connect the white wire of the power line to the chrome screw of the socket assembly.
7.Connect the ground wire of the supply line to the green screw of the socket assembly.
8.Refit the socket assembly back into the electrical box and replace the cover plate. Secure the cable with the clamp on the outside of the
| Inside |
| Electrical Box |
| Retaining |
|
|
| Screw |
|
|
|
| Front | |
|
|
| of Unit |
Outside |
|
| |
|
| of | Unit |
|
| Front | CFM191a |
|
|
| |
Fig. 44 |
|
|
It is strongly suggested that the wiring of the
Ensure that the power to the supply line has been disconnected before com- mencing this procedure.
The
To connect the
1.Unscrew the retaining screw from the plate and remove from the appliance. (Fig. 44)
2.Remove the front cover of the
Ceramic Refractory Kits
Ceramic Refractory Panel Kit #AT1CBB is available for this appliance.
Take care when handling the refractory panels as they are fragile until held in place and supported.
Installation, refer to Figures 45 & 46.
1.Remove the front window frame assembly.
2.Remove the logs.
3.Place the lower supports for the side refractory panels on the base of the firebox. Place each support so that the slotted hole fits over the forward screw head along the edge of the base.
10004798 | 29 |