VERTICAL SIDEWALL INSTALLATIONS

Irving Oil

VERTICAL SIDEWALL INSTALLATIONS

Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to.

The graph, on page 11, showing the relationship between vertical and horizontal side wall venting will help to determine the various lengths allowable.

Minimum clearance between vent pipes and combustible materials is one 1” (25mm) on top, bottom and sides unless otherwise noted.

When the vent termination exits through foundations less than 20” below siding outcrop, the vent pipe must flush up with the siding.

It is always best to locate the fireplace in such a way that minimizes the number of offsets and horizontal vent length.

The horizontal vent run refers to the total length of vent pipe from the flue collar of the fireplace to the face of the outer wall.

Horizontal plane means no vertical rise exists on this portion of the vent assembly.

VERTICAL SIDEWALL APPLICATIONS

The maximum number of 90° elbows per side wall installations is three (3).

For IRFSDV24 and IRFSDV34 models the maximum horizontal run off a minimum 12” vertical rise is 3’ (see Fig. 15).

If a 90˚ elbow is used in the horizontal vent run

(level height maintained) the maximum horizontal vent length is reduced by 36 inches, (Fig. 14). This does not apply if the 90˚ elbows are used to increase or redirect a vertical rise (Fig. 16).

Example: According to the chart the maximum horizontal vent length is 20’ and if a 90˚ elbow is required in the horizontal vent it must be reduced to 17’.

In Fig. 14, Dimension A plus B must not be greater than 17’ (5.2m).

The maximum number of 45° elbows permitted per side wall installation is two (2). These elbows can be installed in either the vertical or horizontal run.

For each 45° elbow installed in the horizontal run,

the length of the horizontal run MUST be reduced by 18” (45cm). This does not apply if the 45° elbows are installed on the vertical part of the vent system.

The maximum number of elbow degrees in a system is 270° (Fig. 13).

10

Example: In Figure 13

 

 

 

Elbow 1

=

90°

 

 

Elbow 2

=

45°

 

 

Elbow 3

=

45°

 

 

Elbow 4

=

90°

 

 

 

 

 

Total angular variation =

270°

Fig. 13

7.5 ft.

 

2286mm

A + B = 17 ft.

 

Fig. 14

3FT (92cm)

 

IRFSDV24

 

IRFSDV24

x

x = 12”

 

Fig. 15

 

 

20 FT

 

 

(610cm)

 

 

PIPE STRAPS

 

 

EVERY 3'

(2286m)

 

(92cm)

 

FIRESTOP/ZERO

7.5FT

PIPE STRAPS

CLEARANCE SLEEVE

 

EVERY 3'

 

 

(92cm)

 

 

 

Fig. 16

 

 

10004000

Page 10
Image 10
Vermont Casting IRFSDV34 Vertical Sidewall Installations, Vertical Sidewall Applications, Irving Oil, x = 12”, IRFSDV24