installations. From 0 to a maximum of 8’ of vent pipe can be used between elbows (Fig. 25).
•7DVCS must be used to support offsets (Fig.
26). This application will require that you first determine the roof pitch and use the appropriate starter kit. (See Venting Components List)
Irving Oil
TO INSTALL VERTICAL VENTING
1. | Locate your fireplace. |
2. | Plumb to center of the (4”) flue collar from ceiling |
| above and mark position. |
3. | Cut opening equal to |
| 240 mm). |
4. | Proceed to plumb for additional openings through |
MAX.
8 FEET
2.44m
45¡
40'(12m)
MAX.
8 FEET
2.44m
45¡
TYPICAL 7DVCS |
APPLICATION |
TYPICAL ROOF |
SUPPORT |
APPLICATION |
| the roof. In all cases, the opening must provide a |
| minimum of 1 inch clearance to the vent pipe, i.e., |
| the hole must be at least |
| 240 mm). |
5. | Place fireplace into position. |
6. | Place firestop(s) #7DVFS or Attic Insulation Shield |
| #7DVAIS into position and secure (Fig. 29). |
7. | Install roof support (Fig. 27) and roof flashing, |
| making sure upper flange of flashing is below the |
| shingles (Fig. 30). |
8. | Install appropriate pipe sections until above the |
| flashing (Fig. 30). |
9. | Install storm collar and seal around the pipe. |
10. | Add additional vent lengths for proper height (Fig. 28). |
11. | Apply high temperature sealant to 4” and 7” collars |
| of vertical vent termination and install. |
Attic |
|
Insulation |
|
Shield | 11" |
| JOIST |
TYPICAL OFFSET INSTALLATION | Fig. 27 |
VENT TERMINATION
ROOF | 2' Min. |
ATTIC INSULATION | |
| JOISTS |
40 FEET | ATTIC INSULATION |
(12.2m) | SHIELD |
|
STORM COLLAR
ROOF FLASHING
ROOF SUPPORT
CEILING JIOSTS
Ceiling | 11" | UPPER FLOOR |
Installation |
| |
|
| |
|
| JOIST |
FIRESTOP
SPACER
NAILS (4) | Fig. 29 |
Fig. 29 If there is a room above ceiling level, firestop spacer must be installed on both the bottom and the top side of the ceiling joists. If an attic is above ceiling level a 7DVAIS (Attic Insulation Shield) must be installed.
The enlarged ends of the vent section always face downward (Fig. 30).
Fig. 28
TYPICAL
The minimum height of the vent above the highest point of penetration through the roof is 2 feet (Fig. 28).
SHEETMETAL |
| |
SCREWS (#5) Ñ | SHEETMETAL | |
3 PER JOINT | ||
SCREWS (#5) Ñ | ||
SEALANT | ||
3 PER JOINT | ||
STORM | SEALANT | |
| ||
COLLAR | STORM |
COLLAR
Fig. 30
10004000 | 15 |