Irving Oil
When using copper or flex connector use only ap- proved fittings. Always provide a union when using black iron pipe so that gas line can be easily disconnected for burner or fan servicing (see Fig. 2) See gas specification for pressure details and ratings.
The fireplace valve must not be subjected to any test pressures exceeding 1/2 psi. Isolate or disconnect this or any other gas appliance control from the gas line when pressure testing.
INSTALLATION OF REMOTE
SWITCH FOR RN/RP GAS VALVE
The remote ON/OFF switch can not be fitted to units using the Honeywell Radio Frequency control valve.
If the fireplace has been fitted with the Radio Frequency Control Valve, the ON/OFF function is controlled by the remote handset. (See the Comfort Control Valve Operating Instruction Section).
Install on/off switch assembly on either the rear right or left side of the Fireplace.
1.Remove the screw at the back of the cabinet top either on the left or the right side of the fireplace.
2.Position switch assembly onto the back of the fireplace, then fasten two screws as shown in Fig. 5.
3.Attach wiring under the clips on the rear casing (Fig. 5) and install wiring through the rear opening of the fireplace before connecting to the valve as shown in Fig. 4.