Vermont Casting VCBV30TP - 30 Attach Mounting Screws to Wall, Preparing for Installation

Models: VCBV30TN VCBV10TP - 10 VCBV20TN VCBV10TN VCBV20TP - 20 VCPV30TN VCPV10TN VCBV30TN, VCBV30TP, VCBV20TN, VCBV20TP, VCBV10TN, VCBV10TP, VCPV30TN, VCPV30YP, VCPV18TN, VCPV18TP, VCPV10TN, VCPV10TP VCPV18TP - 18 VCPV18TN VCPV10TP VCBV30TP - 30 VCPV30TP - 30

1 16
Download 16 pages 42.72 Kb
Page 5
Image 5
Attach Mounting Screws to Wall

Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.

*Aftermarket: Completion of sale, not for purpose of resale from manufacturer.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

CAUTION: If you install the heater in a home garage:

Heater must be at least 18” above floor

Locate heater where moving vehicle will not hit it.

Attach Mounting Screws to Wall

NOTE: Wall anchors and mounting screws are in hardware package provided with heater.

1.Install mounting screws on wall as shown in Figure 3. Use enclosed “paper template” for proper location of holes. Be sure template is level. It may be neces- sary to use plastic or lead anchors for plaster walls.

2.Drill holes at marked locations using 9/64” drill bit. Insert mounting screw.

3.Leave screw head out from wall far enough to attach heater.

Preparing for Installation

1.Remove heater from carton.

2.Remove all protective packaging applied to heater for shipment.

3.Check heater for any shipping damage. If heater is damaged, promptly inform dealer/distributor.

4.Select a location for the heater that will provide maximum exposure of the radiant surface to the room, but will not be subjected to accidental contact.

5.Adequate clearance must be available around the air opening. Refer to Figure 2 for clearances that must be maintained to the side walls, floor and horizontal surface surrounding the heater.

Ceiling Preparing for Installation

 

 

 

36"

 

 

 

 

 

(914 mm)

 

 

 

 

 

 

 

Min.

Adjacent Wall

 

 

 

 

 

 

 

13"

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(330 mm)

 

 

 

 

 

 

 

 

 

Min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screw

 

 

 

20"

 

Holes

 

(508 mm)

 

 

 

 

 

 

 

Min.

A = 21 1/4" (330 mm) @ 30,000 Btu/ hr Model

13 11/16" (347 mm) @ 18,000/20,000 Btu/ hr Model 9 7/8" (251 mm) @ 10,000 Btu/ hr Model

RH110

Fig. 2 Minimum clearances to floor, adjacent walls and ceiling.

Template

Mounting Screws

RH101

Fig. 3 Use paper template supplied to mark location of mounting holes. Be sure template is level.

Wall Anchor Method

When mounting heater to hollow walls (wall areas between studs) or solid walls (concrete or masonry), it may be necessary to use wall anchors.

1.Place paper template on wall maintaining minimum clearance. Be sure template is level.

2.Drill holes at marked locations using 5/16” drill bit. For solid walls, concrete or masonry, drill holes at least 1” deep.

3.Insert plastic anchor. Tap anchor flush to wall. (Fig. 4)

4.Insert screw into wall anchor leaving screw head out far enough from wall to attach heater. (Fig. 4)

5.Hang heater on mounting screws in holes provided at the rear of the heater.

5

Page 5
Image 5
Vermont Casting VCBV30TP - 30, VCPV10TN Attach Mounting Screws to Wall, Preparing for Installation, Wall Anchor Method