3-Wire Conduit Installation
(See Figures 3.1, 3.5 and 3.6)
1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 6 fixing Screws (fig. 3.1).
2.Feed 1/2” (1.3 cm) trade size Conduit through the hole in the Conduit Bracket and secure to the Conduit Bracket with a Conduit Clamp.
3.Remove the 3 wire terminal nuts and washers from the Terminal Block.
4.Plug the terminal holes of conductors. The Neutral or Ground Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block. The Power Wires must be connected to the outside terminals.
5.Plug washers and tighten nuts securely. Do not remove Ground strap.
6.Assemble the Terminal Block Access Plate.
(See Figures 3.1, 3.5 and 3.7)
1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 6 fixing Screws (fig. 3.1).
2.Feed 1/2” (1.3 cm) trade size Conduit through the hole in the Conduit Bracket and secure to the Conduit Bracket with a Conduit Clamp.
3.Remove the 3 wire terminal nuts and washers from the Terminal Block.
4.Remove the Ground Strap from the frame of range and terminal by removing its screw and cutting it as shown in Figure 3.7.
5.Plug the terminal holes of conductors. The Neutral Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block; the Power Wires must be connected to the outside terminals; the Ground Wire must be attached to the frame of range by using the (Ground) identified Grounding Screw.
6.Plug washers and tighten nuts securely.
7.Assemble the Terminal Block Access Plate.