Verona VEFSGG 365 N Injectors Table, Operations To Be Performed When Substituting The Injectors

Models: VEFSGG 365 N

1 28
Download 28 pages 1.47 Kb
Page 20
Image 20
INJECTORS TABLE

INJECTORS TABLE

 

 

 

 

 

LP/PROPANE

NATURAL GAS

BURNERS

NOMINAL POWER

REDUCED POWER

11” W.C.P.

4” W.C.P.

BTU/hr

 

BTU/hr

 

 

 

Ø injector

Ø injector

 

 

 

 

 

 

 

 

[1/100 mm]

[1/100 mm]

 

 

 

 

 

 

 

Semi-rapid (R)

6000

 

1500

72

118

 

 

 

 

 

 

Triple ring (TC)

12000

 

5000

102

170

 

 

 

 

 

 

 

 

Inner crown

2800 for NATURAL GAS (*)

 

1000 (*)

55

80

 

3500 for LP/PROPANE GAS (*)

 

(no. 1 central)

(no. 1 central)

Dual (D)

 

 

 

 

 

 

 

 

 

Outer crowns

16000 for NATURAL GAS (#)

6500

for NATURAL GAS (#)

72

130

 

 

15000 for LP/PROPANE GAS (#)

4500

for LP/PROPANE GAS (#)

(no. 2 outer)

(no. 2 outer)

 

 

 

 

 

 

 

 

 

Oven burner

21000

 

2700

135

247

 

 

 

 

 

 

Broil burner

15000

 

-

115

200

 

 

 

 

 

 

 

(*) Power calculated only with inner crown operating

(#) Power calculated with inner and outer crowns operating

Semi-rapid burner

J

Fig. 2.6a

Triple ring burner

J

Fig. 2.6b

OPERATIONS TO BE

PERFORMED WHEN

SUBSTITUTING THE

INJECTORS

Remove the gratings and the burner covers;

Using a wrench substitute the nozzle injectors “J” (figs. 2.6a - 2.6b - 2.6c) with those most suitable for the kind of gas for which it is to be used.

The burner are conceived in such a way so as not to require the regulation of the primary air.

DUAL burner

J

Injector for inner crown

J

Injectors for outer crowns

Fig. 2.6c

20

Page 20
Image 20
Verona VEFSGG 365 N Injectors Table, Operations To Be Performed When Substituting The Injectors, Semi-rapid burner, 6a, 6b