ADJUSTMENT OF THE OVEN BURNER MINIMUM

 

 

ADJUSTMENT OF THE OVEN BURNER MINIMUM

G

This needs to be done only for the oven burner (the broil is a fixed capacity) by acting

 

on the thermostat in the following way:

 

– Turn on the burner by setting the thermostat knob on position .

 

– Remove the knob and unscrew the by-pass screw “G” (fig. 2.13) about three times

 

by passing a small flat screwdriver (Ø 3 mm blade, 100 mm length) through the panel

 

opening.

 

 

Re-mount the knob and let the oven heat up for about 10 minutes, then bring the knob

 

to position

(minimum) to operate the thermostat by-pass.

 

– After having removed the knob again and being very careful not to turn the tap rod,

 

slowly screw the by-pass screws “G” (fig. 2.13) until you obtain a flame of 3-4 mm

Fig. 2.13

in height.

 

N.B. For LP/PROPANE gas the by-pass screw must be fixed thoroughly.

After regulation repeat the operations indicated in paragraph “2. Pressure regulator” at pages 13 and 18.

If the range has been disconnected and then connected again to the gas supply line repeat the operations indicated in paragraph “5. Leak Testing” at page 18.

IMPORTANT:

After conversion to LP/PROPANE gas has been carried out affix inside the drawer, near the data plate, the conversion label supplied and also affix a conversion label at page 3 of this instruction manual.