CONVERSION TO LP/PROPANE GAS

CONVERSION TO LP/PROPANE GAS

Every range is provided with a set of injectors for the various types of gas.

Select the injectors to be replaced according to the “INJECTORS TABLE”.

The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of each injector.

SETTING THE PRESSURE REGULATOR (fig. 2.5)

The pressure regulator is accessible through the storage compartment by opening the bottom pivoting panel; the pressure regulator is positioned on the rear left side of the range.

To set the pressure regulator:

1.Unscrew the regulator cover;

2.Unscrew the A component, reverse and screw it according to the LP/PROPANE regulation.

Pressure regulator

REGULATOR

COVER

1 SETTING THE PRESSURE REGULATOR (fig. 2.5)

2

A component

LP/PROPANE

NATURAL GAS

REGULATION

REGULATION

Fig. 2.5 19