SETTING THE BURNER MINIMUM
When switching from one type of gas to another, the minimum flow rate must also be correct: the flame should not go out even when passing suddenly from maximum to minimum flame.
To regulate the flame follow the instructions below:
Semirapid and triple ring burners
| |
position | |
|
– With a thin screwdriver turn the screw "F" until adjustment is correct (fig. 2.7).
Inside crown of DUAL burner
| |
position | |
|
– Using a screwdriver turn the screw "H" until the correct setting is obtained (fig. 2.8).
Outside crowns of DUAL burner
| |
position | |
|
– Using a screwdriver turn the screw "G" until the correct setting is obtained (fig. 2.8).
For LP/PROPANE gas, tighten the adjustment screws completely.
regulation |
screw |
Fig. 2.7 |
H |
G |
Fig. 2.8 |