Verona VEFSGG 365 N warranty Setting The Burner Minimum, Semirapid and triple ring burners

Models: VEFSGG 365 N

1 28
Download 28 pages 1.47 Kb
Page 21
Image 21
SETTING THE BURNER MINIMUM

SETTING THE BURNER MINIMUM

When switching from one type of gas to another, the minimum flow rate must also be correct: the flame should not go out even when passing suddenly from maximum to minimum flame.

To regulate the flame follow the instructions below:

Semirapid and triple ring burners

–  Light the burner

 

–  Set the gas valve to

position

–  Remove the knob

 

– With a thin screwdriver turn the screw "F" until adjustment is correct (fig. 2.7).

Inside crown of DUAL burner

–  Light the DUAL burner

 

–  Set the gas valve to

position

–  Remove the knob

 

– Using a screwdriver turn the screw "H" until the correct setting is obtained (fig. 2.8).

Outside crowns of DUAL burner

–  Light the DUAL burner

 

–  Set the gas valve to

position

–  Remove the knob

 

– Using a screwdriver turn the screw "G" until the correct setting is obtained (fig. 2.8).

For LP/PROPANE gas, tighten the adjustment screws completely.

regulation

screw

Fig. 2.7

H

G

Fig. 2.8

21

Page 21
Image 21
Verona VEFSGG 365 N warranty Setting The Burner Minimum, Semirapid and triple ring burners, Inside crown of DUAL burner