SECTION 2-INSTALLATION

3. Hinges and Lock Keeper

a.Refer to Figure 2-3. To remove the hinge base from the cabinet fascia, unscrew the three phillips type machine screws.

Figure 2-3

SECTION 2-INSTALLATION

D.Rehingeability (One & Two Section Long Door Cabinet)

1.Remove door from cabinet by opening it about 90° and lifting it from it’s supporting brackets (as mentioned on page 7).

2.Carefully pry the hinge barrel cover from hinge barrel (Fig 2-5).

b.To remove lock keeper (“D” shaped metal stamping for lock bolt), use a 5/16” open end wrench. Remove the two #10-32 screws attaching keeper to fascia. Reverse procedure to reinstall. Refer to Figure 2-4.

Figure 2-4

Lock Keeper

Figure 2-5

3.Remove hinge barrels from door, turn them upside down and replace on door (Figure 2-6).

Figure 2-6

7

Page 13
Image 13
Victory Refrigeration V-Series manual Hinges and Lock Keeper, Rehingeability One & Two Section Long Door Cabinet