On-Screen Display Menus
Fan Control
Lamp Reset Timer
Remote Control
Return to User OSD
Select Fan Control from the Service Menu to control the operation of the projector’s cooling fan.
Mode: In most cases, the default Fan Control Mode (Auto Normal) will maintain the correct operating temperature. If the lamp frequently turns off due to overheating, or in certain
Fan Speed: If you set the Fan Mode to Manual, select Fan Speed and use the
After changing either of these settings, press EXIT to return to the previous menu.
When you replace the projector lamp, you should also reset the lamp timer. To do this, select Lamp Reset Timer from the Set Up menu. Press the
NOTE: Reset the Lamp Timer ONLY after you replace the lamp. Otherwise, the reported “Lamp Hours” will be inaccurate.
WARNING! Do not exceed the recommended lamp life of 2000 hours. An old lamp becomes increasingly fragile and prone to sudden failure.
Press the ▲ or ▼ arrows to select the projector’s
The Remote Control menu shows you the primary and secondary infrared (IR) codes assigned to the Vision Model 50. The Primary IR code is permanently set to +20. The secondary IR code is also +20.
You can change the secondary IR code if either:
•Another device in the theater (a DVD player, for example) is responding to commands from the Model 50 remote control in ways that are unpredictable or undesirable.
•You have multiple Model 50 projectors and want to control them independently, as opposed to broadcasting commands from a single remote to all of them. In this scenario, you can use multiple remotes programmed to use different IR codes. Or, you can use a single remote and change the IR code as needed to address a specific projector.
When you change the secondary IR code, the remote sends that code instead of the primary IR code.
NOTE: The Remote Control menu is
To simultaneously change the secondary IR code and |
|
| |
Remote Control |
| ||
synchronize that remote with a projector, point the remote at |
| ||
Secondary | 20 | ||
the projector, then press and hold ◄ and ► simultaneously | |||
for five seconds. The Remote Control edit window, shown at |
|
| |
right, appears. Type a new, |
|
|
The procedure for changing the secondary IR code on the remote only is the same, except that you point the remote away from the projector.
To exit the Service menu, use the up- or
To return to the Service menu, select it from the Main Menu, press ENTER twice, then press MENU on the remote control. (You do not need to
44 | Vidikron Vision Model 50 Owner’s Operating Manual |