Other Information

3. Command Description

 

 

Length

Total Byte of Message excluding “CR”

 

 

TV ID

Identification for each of TV

 

 

Command Type

Identify command type,

 

 

 

“s” (0x73h) : Set Command

 

 

 

“g” (0x67h) : Get Command

ENGLISH

 

 

 

 

“r” (0x72h) : Reply Command

 

 

“p” (0x70h) : RCU Pass-through

 

 

 

 

 

 

“+” (0x2Bh) : Valid command Reply

 

 

 

“-” (0x2Dh) : Invalid command Reply

 

 

 

 

 

 

Command

Function command code: One byte ASCII code

 

 

 

Value[1~3]

Three bytes ASCII that defines the value

 

 

CR

0x0D

4. Set-Function Listing

The PC can control the LCD Monitor for specific actions. The Set-Function command allows you to control the LCD monitor behavior in a remote sit through the RS232 port. The Set-Function packet format consists of 11 bytes.

Set-Function description:

Length

 

Total Byte of Message excluding “CR”

 

 

 

TV ID

 

Identification for each of TV. The TV ID doesn’t be supported by

 

 

 

HDTV “power on” command.

 

 

 

 

 

 

 

If we want to set all TV settings, TV ID can use “99” to achieve, and it

 

 

 

will not have Reply command on this function.

 

 

 

 

 

 

 

 

 

 

 

 

 

Command Type

Identify command type,

 

 

 

 

 

 

 

“s” (0x73h) : Set Command

 

 

 

 

Command

 

Function command code: One byte ASCII code

 

 

Value[1~3]

 

Three bytes ASCII that defines the value

 

 

 

CR

 

0x0D

 

 

 

 

 

 

 

Set-Function format:

 

 

 

 

 

 

 

Send (Command Type= “s”)

 

 

 

 

 

 

 

Name

 

Length

 

ID

Command

Command

 

Value1

Value2

Value3

CR

 

 

 

 

 

Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte Count

 

1 Byte

 

2 Byte

1 Byte

1 Byte

 

1 Byte

1 Byte

1 Byte

1 Byte

 

 

 

 

 

 

 

 

 

 

 

 

Bytes order

 

1

 

2~3

4

5

 

6

7

8

9

(Command Type= “s”, Only for HDTV power on)

 

 

 

 

Name

 

Length

 

Command

Command

Value1

 

Value2

Value3

CR

 

 

 

 

 

Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte Count

 

1 Byte

 

1 Byte

1 Byte

1 Byte

 

1 Byte

1 Byte

1 Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

Bytes order

 

1

 

2

3

4

 

5

6

7

 