IMPORTANT–Please Read and Follow!
IMPORTANT– Please Read and Follow
ELECTRICALW ASHOCKR N HAZARDI N G
• Electrically ground dishwasher.
• Connect ground wire to green ground connector in terminal box.
• DO NOT use an extension cord.
• Failure to follow these instructions, can result in death, fire or electrical shock.
TIP OVERWHAZARDA R N I N G
• DO NOT use dishwasher until completely installed.
• DO NOT push down on open door.
• Doing so can result in serious injury or cuts.
EXCESSIVEW AWEIGHTR N IHAZARDN G Use two or more people to move and install dishwasher. Failure to do so can result in back or other injury.
W A R N I N G
Plumbing connections must comply with applicable sanitary, safety, and plumbing codes.
C A U T I O N
The dishwasher has a factory installed backflow preventer. Do Not add an additional check valve.
W A R N I N G
Disconnect the electrical power supply and place a tag at the disconnect switch indicating that you are working on the circuit.
W A R N I N G
Be sure electrical power is turned off at circuit breaker or fuse box before servicing or installing unit. Do not use an extension cord for this appliance.
W A R N I N G
Improper connection of the equipment – grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance; if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
shall be used if required by
• The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture.
• Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which are not installed properly or
do not meet the requirements below.
If the use of a GFI is required, it should be:
•Of the receptacle type (breaker type or portable type NOT recommended)
•Used with permanent wiring only (temporary or portable wiring NOT recommended)
•On a dedicated circuit (no other receptacles, switches or loads in the circuit)
•Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT recommended)
•Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard
•In good condition and free from any
•Protected from moisture (water, steam, high humidity) as much as reasonably possible