Heart-Rate-Control function does not work

Possible causes:

1.Transmitter does not contact with user's chest very well.

2.Transmitter(Polar-belt) is at low battery status.

3.Transmitter(Polar-belt) is damaged.

4.Heart-rate-control board is damaged.

5.PCB is damaged.

Fix:

1.Center the transmitter on your chest below the pectoral muscle(breast) as shown, then check again.

2.Remove the battery cover of the transmitter. Replace a new battery and check again.

￿Actually, as moisture may activate the transmitter, please dry transmitter after use.

3.OR Transmitter is damaged. Replace the Transmitter.

4.OR Heart-rate-control board is damaged. Replace the HR-control board.

5.OR PCB is damaged. Replace the PCB.