VIVOTEK
User's Manual - 167
URL Command Document for All SeriesIP8130W/IP8131W
patrolseq string[120] <blank> 1/4 The patrol sequence of ePTZ. All the
patrol position indexes will be
separated by ","
patroldwelling string[160] <blank> 1/4 The dwelling time (unit: second) of
each patrol point, separated by “,”.
preset_i<0~19>_name string[40] <blank> 1/7 Name of ePTZ preset.
(It should be set by ePreset.cgi rather
than by setparam.cgi.)
preset_i<0~19>_pos <coordinate> <blank> 1/7 Left-top corner coordinate of the
preset.
(It should be set by ePreset.cgi rather
than by setparam.cgi.)
preset_i<0~19>_size <window size> <blank> 1/7 Width and height of the preset.
(It should be set by ePreset.cgi rather
than by setparam.cgi.)
7.32 IR cut control

Group: ircutcontrol (capability.nvideoinprofile > 0) (IP8131W Only)

NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
mode auto,
day,
night,
di,
schedule
auto 6/6 Set IR cut control mode

sir <boolean> 16/6 Enable/disable Smart IR

daymodebegintime 00:00~23:59 07:00 6/6 Day mode begin time
daymodeendtime 00:00~23:59 18:00 6/6 Day mod end time
disableirled <boolean> 0 6/6 Enable/disable built-in IR led
(capability.ir > 0)
bwmode <boolean> 0 6/6 Switch to B/W in night mode if
enabled
sensitivity low,
normal,
high
normal 6/6 Sensitivity of light sensor
enableextled <boolean> 0 1/6 Enable/disable external IR led
(capability.extir > 0)