Vivotek IP8151 manual Vivotek, begintime, Users Manual

Models: IP8151

1 179
Download 179 pages 60.65 Kb
Page 149
Image 149
Manual background

VIVOTEK

begintime

hh:mm

6/6

Begin time of the weekly schedule.

 

 

 

 

endtime

hh:mm

6/6

End time of the weekly schedule.

 

 

 

(00:00 ~ 24:00 sets schedule as always on)

 

 

 

 

lowlightcondition

0, 1

6/6

Switch on white light LED in low light condition

<product dependent>

 

 

0 => Do action at all times

 

 

 

1 => Do action in low-light conditions

 

 

 

 

action_do_i<0~(ndo-1)

0, 1

6/6

Enable or disable trigger digital output.

>_enable

 

 

 

 

 

 

 

action_do_i<0~(ndo-1)

1~999

6/6

Duration of the digital output trigger in seconds.

>_duration

 

 

 

 

 

 

 

action_goto_enable

<Boolean>

6/6

Enable/disable ptz goto preset position on event

<product dependent>

 

 

triggered.

 

 

 

 

action_goto_name

string[40]

6/6

Specify the preset name that ptz goto on event

<product dependent>

 

 

triggered.

 

 

 

 

action_cf_folder

string[128]

6/6

Path to store media.

 

 

 

 

action_cf_media

NULL, 0~4

6/6

Index of the attached media.

 

 

 

 

action_cf_datefolder

<boolean>

6/6

Enable this to create folders by date, time, and hour

 

 

 

automatically.

 

 

 

 

action_server_i<0~4>_e

0, 1

6/6

Enable or disable this server action.

nable

 

 

 

 

 

 

 

action_server_i<0~4>_

NULL, 0~4

6/6

Index of the attached media.

media

 

 

 

 

 

 

 

action_server_i<0~4>_

<boolean>

6/6

Enable this to create folders by date, time, and hour

datefolder

 

 

automatically.

 

 

 

 

action_patrol_enable

<Boolean>

6/6

Enable/disable ptz patrol when event triggered.

(only for VS series)

 

 

 

<product dependent>

 

 

 

 

 

 

 

action_ patrol _server

0~255

6/6

Indicate the target servers to which the snapshots

(only for VS series)

 

 

taken during patrol dwelling time should be sent.

<product dependent>

 

 

One bit represents one application server

 

 

 

(server_i0~i4).

 

 

 

bit0 (LSB) = server_i0.

 

 

 

bit1 = server_i1.

 

 

 

bit2 = server_i2.

 

 

 

bit3 = server_i3.

 

 

 

bit4 = server_i4.

 

 

 

For example, enable server_i0, server_i2, and

 

 

 

server_i4 as notification servers; the notifyserver

 

 

 

value is 21.

 

 

 

 