VIVOTEK

 

night,

 

 

 

schedule

 

 

 

 

 

 

profile_i<0~(m-1)>_beginti

hh:mm

4/4

Begin time of schedule mode.

me

 

 

 

 

 

 

 

profile_i<0~(m-1)>_endtim

hh:mm

4/4

End time of schedule mode.

e

 

 

 

 

 

 

 

profile_i<0~(m-1)>_win_i<

<boolean>

4/4

Enable motion window.

0~2>_enable

 

 

 

 

 

 

 

profile_i<0~(m-1)>_win_i<

string[14]

4/4

Name of motion window.

0~2>_name

 

 

 

 

 

 

 

profile_i<0~(m-1)>_win_i<

0 ~ 320

4/4

Left coordinate of window position.

0~2>_left

 

 

 

 

 

 

 

profile_i<0~(m-1)>_win_i<

0 ~ 240

4/4

Top coordinate of window position.

0~2>_top

 

 

 

 

 

 

 

profile_i<0~(m-1)>_win_i<

0 ~ 320

4/4

Width of motion detection window.

0~2>_width

 

 

 

 

 

 

 

profile_i<0~(m-1)>_win_i<

0 ~ 240

4/4

Height of motion detection window.

0~2>_height

 

 

 

 

 

 

 

profile_i<0~(m-1)>_win_i<

0 ~ 100

4/4

Percent of motion detection window.

0~2>_objsize

 

 

 

 

 

 

 

profile_i<0~(m-1)>_win_i<

0 ~ 100

4/4

Sensitivity of motion detection window.

0~2>_sensitivity

 

 

 

<product dependent>

 

 

 

 

 

 

 

7.15 Tampering detection settings

Group: tampering_c<0~(n-1)>for n channel product (product dependent)

 

NAME

 

 

VALUE

 

 

SECURITY

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

(get/set)

 

 

 

 

 

enable

 

 

<boolean>

 

4/4

 

 

Enable or disable tamper detection.

 

 

 

 

 

 

 

 

 

 

 

 

threshold

 

0 ~ 255

 

4/4

 

 

Threshold of tamper detection.

 

 

 

 

 

 

 

 

 

 

 

 

duration

 

10 ~ 600

 

4/4

 

 

If tampering value exceeds the ‘threshold’ for

 

 

 

 

 

 

 

 

 

 

 

more than ‘duration’ second(s), then tamper

 

 

 

 

 

 

 

 

 

 

 

detection is triggered.

 

 

 

 

 

 

 

 

 

 

 

 

 

122 - User's Manual

Page 122
Image 122
Vivotek IP8330, 8332 user manual Tampering detection settings