VIVOTEK

PARAMETER

 

VALUE

 

SECURITY

 

DESCRIPTION

 

 

 

 

 

(get/set)

 

 

 

cyclic_enabled

 

<boolean>

 

6/6

 

Enable cyclic storage method.

 

 

 

 

 

 

 

autocleanup_enabled

 

<boolean>

 

6/6

 

Enable automatic clean up method.

 

 

 

 

 

 

Expired and not locked media files will be deleted.

 

 

 

 

 

 

 

autocleanup_maxage

 

<positive integer>

 

6/6

 

To specify the expired days for automatic clean up.

 

 

 

 

 

 

 

 

7.31 Region of interest (IP8332 ONLY)

Group: roi_c<0~(n-1)>for n channel product, and m is the number of streams which support ROI.

PARAMETER

 

VALUE

 

SECURITY

 

DESCRIPTION

 

 

 

 

 

(get/set)

 

 

 

s<0~(m-1)>_home

 

<coordinate>

 

6/6

 

ROI left-top corner coordinate.

 

 

 

 

 

 

 

 

s<0~(m-1)>_size

 

<window size>

6/6

 

ROI width and height. The width value must be

 

 

 

 

 

 

 

multiples of 16 and the height value must be

 

 

 

 

 

 

 

multiples of 8

 

 

 

 

 

 

 

 

 