VIVOTEK
NOTE
►Up to 5 privacy mask windows can be set up on the same screen.
►If you want to delete the privacy mask window, please click the ‘x’ on the upper
Sensor Settings Advanced Mode
Click Sensor Settings to open the Sensor Settings page. On this page, you can set the maximum exposure time, exposure level, and AGC (Auto Gain Control) settings.
You can configure two sets of sensor settings: one for normal situations, the other for special situations, such as day/night/schedule mode.
2010/01/13 13:44:17
Sensor Setting 1:
For normal situations
Sensor Setting 2:
For special situations
Exposure
■Maximum Exposure Time: Select a proper maximum exposure time according to the light source of the surroundings. Shorter exposure times result in less light. The exposure times are selectable for the following durations:
For IP8330: 1/480 second, 1/240 second, 1/120 second, 1/60 second, 1/30 second, 1/15 second, and
1/5 second. If you want to set up 60 fps, please select 1/60 second.
For IP8332: 1/30 second, 1/15 second, and 1/5 second.
■Exposure level: You can manually set the Exposure level, which ranges from 1 to 8 (dark to bright).The default value is 4.
■Max gain (Auto Gain Control): You can manually set the AGC level (2X 4X, or 8X). The default value is 4X.
56 - User's Manual