VIVOTEK
96 - User's Manual
mdwin <integer> 6/6 Indicate which motion detection windows detect.
This field is required when trigger condition is “md”.
One bit represents one window.
The LSB indicates the 1st window.
For example, to detect the 1st and 3rd windows, set
mdwin as 5.
inter 1~999 6/6 Interval of snapshots in minutes.
This field is used when trigger condition is “seq”.
weekday 0~127 6/6 Indicate which weekday is scheduled.
One bit represents one weekday.
bit0 (LSB) = Saturday
bit1 = Friday
bit2 = Thursday
bit3 = Wednesday
bit4 = Tuesday
bit5 = Monday
bit6 = Sunday
For example, to detect events on Friday and
Sunday, set weekday as 66.
begintime hh:mm 6/6 Begin time of the weekly schedule.
endtime hh:mm 6/6 End time of the weekly schedule.
(00:00 ~ 24:00 sets schedule as always on)
action_do_i<0~(ndo-1)
>_enable
0, 1 6/6 Enable or disable trigger digital output.
action_do_i<0~(ndo-1)
>_duration
1~999 6/6 Duration of the digital output trigger in seconds.
action_server_i<0~4>_e
nable
0, 1 6/6 Enable or disable this server action.
The default value is 0.
action_server_i<0~4>_
media
NULL, 0~4 6/6 Index of the attached media.
Group: server_i<0~4>
PARAMETER VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
name string[40] NULL 6/6 Identification of this entry