ftp

upload snapshots by FTP

 

 

 

suffix

<not required>

FTP file with date and time suffix

 

 

 

delay

<integer>

seconds delay to detect next event

 

 

 

inter

<integer>

seconds delay to capture post-event

 

 

 

dihigh

< not required >

set DI high as trigger condition

 

 

 

dilow

< not required >

set DI low as trigger condition

 

 

 

dirise

< not required >

set DI rising as trigger condition

 

 

 

difall

< not required >

set DI falling as trigger condition

 

 

 

motion1

< not required >

set motion window1 as trigger

 

 

condition

 

 

 

motion2

< not required >

set motion window2 as trigger

 

 

condition

 

 

 

motion3

< not required >

set motion window3 as trigger

 

 

condition

 

 

 

ioalarm

< not required >

trigger DO when DI condition

 

 

matched

 

 

 

mdalarm

< not required >

trigger DO when motion detected

 

 

 

ioupload

< not required >

upload snapshot when DI condition

 

 

matched

 

 

 

mdupload

< not required >

upload snapshot when motion

 

 

detected

 

 

 

sinter

<integer>

seconds interval for sequential mode

 

 

 

sbegin

<hh:mm:ss>

time to start sequential mode

 

 

 

send

<hh:mm:ss>

time to stop sequential mode

 

 

 

- 60 -

www.vivotek.com

T:886-2-82455282 F: 886-2-82455532

Page 66
Image 66
Vivotek PT3117, PT3127 manual Seconds delay to capture post-event