LIGHTING AND SHUTTING DOWN PILOT

LIGHTING AND SHUTTING DOWN PILOT

1.Turn on main gas supply.

2.Turn burner valve ON and purge air from line. Turn burner valve OFF.

3.Wait 5 minutes, then turn burner valve ON and depress ignition button. Using a lit taper, ignite oven pilot (Fig. 5). Continue to hold button in for approximately 30 seconds, then release.

4.If pilot goes out, turn burner valve off and wait 5 minutes before relighting.

5.Repeat this procedure until pilot stays lit.

6.Set thermostat to desired temperature.

Lighting instructions also may be found on the oven control panel.

OVEN PILOT LIGHTER

Fig. 5

Shutdown

1.Turn burner valve OFF.

2.Turn thermostat OFF.

Extended Shutdown

1.Turn burner valve OFF.

2.Turn thermostat OFF.

3.Turn main gas supply OFF.