C24GA SERIES GAS CONVECTION STEAMERS
Gas Connection Data
FLEXIBLE GAS CONNECTORS BTU/hr. FLOW CAPACITY 1, 2
|
| LENGTH 3 |
|
| LENGTH 3 |
| ||
| End Fittings - (1) Quick Disconnect | End Fittings - Both Threaded | ||||||
|
| & (1) Threaded |
|
|
|
|
| |
ID | 36" | 48" | 60" | 72" | 36" | 48" | 60" | 72" |
1/2" | 77,000 | 68,000 | 60,000 | 55,000 | 120,000 | 106,000 | 93,000 | 86,000 |
3/4" | 218,000 | 180,000 | 158,000 | 139,000 | 256,000 | 225,000 | 198,000 | 175,000 |
1" | 379,000 | 334,000 | 294,000 | 279,000 | 512,000 | 451,000 | 397,000 | 350,000 |
11/4" | 615,000 | 541,000 | 476,000 | 419,000 | 946,000 | 833,000 | 733,000 | 645,000 |
1.Flow rating BTU/hr. 0.64 SP. GR @ 0.5 inch W.C. pressure drop.
2.BTU/hr. flow capacities are based on Dormont Mfg. Co.
3.The maximum length for a flexible gas connector is 72" per National Fuel Code standards.
BLACK IRON PIPE BTU/hr. FLOW CAPACITY 1, 2, 3
Natural Gas |
| Nominal Inside Diameter of Pipe |
|
| ||
Pipe Length | 1/2" | 3/4" | 1" | 11/4" | 11/2" | 2" |
15' | 76,000 | 172,000 | 345,000 | 750,000 | 1,220,000 | 2,480,000 |
30' | 52,000 | 120,000 | 241,000 | 535,000 | 850,000 | 1,780,000 |
45' | 43,000 | 99,000 | 199,000 | 435,000 | 700,000 | 1,475,000 |
60' | 38,000 | 86,000 | 173,000 | 380,000 | 610,000 | 1,290,000 |
75' |
| 77,000 | 155,000 | 345,000 | 545,000 | 1,120,000 |
90' |
| 70,000 | 141,000 | 310,000 | 490,000 | 1,000,000 |
1.Flow rating BTU/hr. 0.64 SP. GR @ 0.3 inch W.C. pressure drop.
2.BTU/hr. flow capacities are based on Schedule 40 pipe, include a tolerance for pressure losses in gas piping systems are provided for reference.
3.Count each 90° elbow as 3' of gas pipe for the purpose of calculating total pipe length.
— 9 —