Vulcan-Hart ECO6D ML-52504 Electrical Connections, Refer to Electrical Data chart on page

Models: ECO4D ML-52502 ECO6C ML-52505 ECO6D ML-52504 ECO4S ML-52501 ECO4C ML-52503

1 20
Download 20 pages 13.49 Kb
Page 7
Image 7
Refer to Electrical Data chart on page 5.

Electrical Connections

WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.

WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT.

Ensure that the electrical power supply agrees with the specifications on the oven data plate and complies with the wiring diagram on the oven.

1.Attach the power leads (furnished as part of the stack set) to the line side of the terminal block of the upper oven. Then carefully route these leads down through the conduit nipple and behind the control panel of the lower oven.

2.Attach these leads to the lower oven terminal block per the wiring diagram. At the same time, attach the power supply conduit to the bottom of the lower oven. Also attach the power supply leads to the line side of the terminal block.

3.Finally, inspect and check all wiring and terminal connections for tightness and proper routing away from any moving parts (relay solenoid core), or pinch points (cover on oven frame). Then carefully replace the oven control panel for both ovens.

Refer to Electrical Data chart on page 5.

LEVELING

Adjust the legs to ensure that the oven racks are level in the final installed position by turning the bottom hex tips on the floor.

CASTERS

If the stacked ovens are to be installed on casters, assemble the casters to the legs provided. Place the locking casters on the front legs and non-locking casters on the rear legs.