Care of the Stainless Steel Housing

DO NOT - Use grill cleaners on the platen.

Life of the non-stick coating of the platen will vary depending upon the product cooked and the cooking temperature, but its life can be extended by frequent cleaning and by using care not to scratch the surface.

When sticking of product eventually occurs and cannot be eliminated by thorough cleaning with a soft cloth and water, it will be necessary to replace the platen surface (see MAINTENANCE).

Care of the Stainless Steel Housing

The outside stainless steel portion of the platen can be cleaned with a mild detergent and stainless steel polish.

MAINTENANCE

WARNING: THE DUPLEX COOKER AND ITS PARTS ARE HOT. BE CAREFUL WHEN OPERATING, CLEANING OR SERVICING THE DUPLEX COOKER.

WARNING: TURN OFF ALL ELECTRIC AND GAS CONTROLS AND ALLOW TO COOL BEFORE PERFORMING ANY MAINTENANCE.

The following routine maintenance is suggested.

1.Burner air shutter openings must be kept clean.

2.Burner ports must be kept clean. To clean burners, boil them in a detergent and water solution for 15 to 20 minutes. Then either brush with a wire brush or clean gas ports with a sharp pointed metal instrument to ensure open ports.

3.Burner pilot flash tubes and burner ignition port must be clear for burners to ignite properly from the pilot.

4.Check the flue for obstructions on an annual basis.

5.To recalibrate the thermostat, contact your Vulcan-Hart authorized servicer.

REPLACEMENT OF THE PLATEN SURFACE

Contact your Vulcan-Hart authorized servicer for replacement kits for platen surfaces.

— 11 —