Vulcan-Hart GDC72 ML-52585 Stand Fig, Gas Connections, Testing The Gas Supply Piping System

Models: GDC24 ML-52581 GDC60 ML-52584 GDC48 ML-52583 GDC36 ML-52582 GDC72 ML-52585

1 16
Download 16 pages 21.24 Kb
Page 5
Image 5
Stand (Fig. 1)

Fig. 1

Stand (Fig. 1)

1.Thread leg extension into fixed nut in griddle frame.

2.Thread adjustable leg through undershelf into leg extension.

3.Tighten both leg extension and adjustable legs.

4.If casters are furnished instead of adjustable legs, the locking swivel casters must be placed in the front.

5.To level the griddle plate, turn the adjustment screw at the bottom of each leg.

GAS CONNECTIONS

Make the gas connection to the appropriate location on the cooker according to applicable codes. Make sure the pipes are clean and free of obstructions, dirt, and piping compound.

CAUTION: All gas supply connections and any pipe joint compound must be a type that is resistant to the action of liquified petroleum gases.

Codes require that a gas shutoff valve be installed in the gas line ahead of the duplex cooker.

WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS. USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.

After piping has been checked for leaks, fully purge gas pipes to remove air.

TESTING THE GAS SUPPLY PIPING SYSTEM

When test pressures exceed 1/2 psig (3.45 kPa), the cooker and its individual shutoff valve must be disconnected from the gas supply piping system.