OPERATION

ELECTRIC STATIONARY KETTLES

OPERATION

VENTING : The kettle and its parts are hot. Use care when operating, clean- ing or servicing the kettle.

VENTING

Whilethekettleiscold,checkthevacuum/pressure gauge. The gauge should be in the vacuum zone measuringbetween20to30in.Hg(84to100kPa). If not, there is air in the jacket and it must be removed by venting for proper heating. Perform the VENTING procedure located in the MAINTENANCE section of this manual.

RESERVOIR JACKET

WATER LEVEL CHECK

During use, the reservoir water level must be maintained high enough to submerge the heating elements. If the low water light is illuminated during use, perform the FILLING THE RESERVOIR JACKET procedure located in the MAINTENANCE section of this manual.

DAILY OPERATION

1.Press the power switch to the ON position.

2.Preheat the kettle by placing the thermostat knob at Simmer/Boil (desired setting) and wait until the temperature light cycles off.

Food products with milk or egg base should be placed into a cold kettle before cooking. Avoid sudden contact of these food products to a hot kettle surface because they stick to the surface.

3.Pour the food to be cooked into the kettle.

TILTING KETTLES

The low water indicator light (red) should not be lit when kettle is in upright position during operation. This light indicates that the elements have been automatically shut off by the kettle’s safety circuity. It is, however, normal for the low water light (red light) to come on when the kettle is in a tilited posistion.

30

60

90

0

120

30

150

Fig. 4 Kettle Controls

CONTROLS AND INDICATORS

CONTROL

FUNCTION

 

 

Vacuum

Indicates the vacuum (in

Pressure

inches) and pressure

Gauge

( in PSI) inside the

 

kettle jacket.

 

 

Thermostat

Regulates kettle temperature

Knob

from warm to a rolling boil.

 

 

Low Water

When lit, indicates

Indicator

insufficient water in the

(Red)

kettle jacket and the sensing

 

probe has interrupted power

 

supply to the controls and to

 

the heating element.

 

 

Power ON/OFF

Controls power to the kettle.

Switch

 

 

 

Power ON

When lit, indicates

Indicator

machine on/powered.

(Amber)

 

 

 

Heater

When lit, indicates the

Light (Amber)

heating element is turned on.

 

 

— 8 —