Vulcan-Hart K60ETL, K40ETL Minimum Clearance Requirements And Recommended, Floor Drain Locations

Models: K20EL K20ETL K60EL K40EL K40ETL K60ETL

1 16
Download 16 pages 22.42 Kb
Page 6
Image 6
MINIMUM CLEARANCE

ELECTRIC STATIONARY KETTLES

MINIMUM CLEARANCE

REQUIREMENTS AND RECOMMENDED

FLOOR DRAIN LOCATIONS

No side and back clearance required, except for operation and service requirements.

INSTALLATION PROCEDURE

Level the kettle by making necessary adjustments using the flanged feet.

1.Place a spirit level on the rim of the kettle with the cover open. Adjust the feet to level the kettle left-to-right and front-to-back.

2.Mark anchoring hole locations through the flanged feet.

3.With hole location marked, drill holes to accommodate 5/16" studs.

4.Reposition the kettle.

5.Bolt the kettle down and apply an NSF approved silicone sealant around the bolt heads and flange making contact with floor surface. Wipe off excess sealant immediately.

Fig 3. Floor Drain Location

— 6 —

Page 6
Image 6
Vulcan-Hart K60ETL, K40ETL Minimum Clearance Requirements And Recommended, Floor Drain Locations, Installation Procedure