TROUBLESHOOTING

ELECTRIC STATIONARY KETTLES

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSES / SUGGESTED CORRECTIVE ACTION

 

 

Unit not Heating

ON/OFF switch OFF / ON/OFF switch ON.

 

Thermostat not on / Turn thermostat on.

 

No power / Check power supply.

 

Water level too low / Add water.

 

Malfunctioning power ON/OFF switch / Contact Authorized

 

Vulcan-Hart Service Provider.

 

Malfunctioning thermostat / Contact Authorized Vulcan-Hart

 

Service Provider.

 

Contactors not connecting heating element to power source / Contact

 

Authorized Vulcan-Hart Service Provider.

 

 

Unit not heating to

Thermostat not on / Turn thermostat on.

desired temperature

Malfunctioning thermostat / Contact Authorized Vulcan-Hart

 

 

Service Provider.

 

 

Draw valve is leaking

Check and clean any food residue with an extremely fine emery cloth.

 

Replace the “O” ring.

 

 

— 14 —