PLUG VALVE CLEAINING

ELECTRIC STATIONARY KETTLES

 

PLUG VALVE CLEAINING

NOTE: 1. Care should be taken not to

INSTRUCTIONS

scratch, ding or dent the valve

 

plug to prevent valve leakage.

Daily Before Operation

Install draw off valve plug:

1.Apply PetroGel lubricant to valve tapered face.

2.Holding the valve handle, slide the plug down into the valve body.

3.Install the bottom washer, making sure to align the key with the groove in the valve plug.

4.Install the retaining ring and hand tighten.

NOTE: If the valve is hard to open the ring has been overtightened.

Daily After Use

Remove draw-off valve plug for cleaning.

1.Unscrew the retaining ring and remove it and the bottom washer.

2.Pull the valve plug straight up to remove from valve body.

3.Wash valve body, plug, washer and retaining ring with mild soap and water.

4.Leave assembly apart to air dry.

2.If multiple kettles are in use care should be taken keep each plug separate and returned to its original valve body.