Vulcan-Hart K40ETL Electrical Connection, Electrical Specifications, Amperage per Line, Minimum

Models: K20EL K20ETL K60EL K40EL K40ETL K60ETL

1 16
Download 16 pages 22.42 Kb
Page 7
Image 7
ELECTRICAL CONNECTION

ELECTRIC STATIONARY KETTLES

ELECTRICAL CONNECTION

ELECTRICAL SPECIFICATIONS : Electrical and ground- ing connections must comply with appli- cable portions of the National Electric Code and/or other local electrical codes.

Amperage per Line Disconnect electrical power to the machine and follow Lockout/ Tagout procedures.

1.Open the control box.

2.Using the wiring diagram for reference, connect electric supply to terminal block.

ELECTRICAL SPECIFICATIONS

 

 

 

Amperage per Line

 

Minimum

 

MODEL

kW

PHASE

 

 

 

Circuit Ampacity

 

 

 

208V

240V

480V

208V

 

240V

 

480V

K20EL/ELT

12

1

57.7

75

 

 

 

 

3

33.3

14.4

45

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

16

1

66.7

 

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

38.5

 

50

 

 

 

 

 

 

 

 

 

 

 

 

K40EL/ELT

18

3

50.0

43.3

21.7

65

 

55

 

30

K60EL/ELT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K40EL/ELT

24

3

66.6

57.7

28.9

85

 

75

 

40

K60EL/ELT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K60EL/ELT

33

3

91.6

79.4

39.7

115

 

100

 

50

 

 

 

 

 

 

 

 

 

 

 

— 7 —

Page 7
Image 7
Vulcan-Hart K40ETL Electrical Connection, Electrical Specifications, Amperage per Line, Minimum, Model, Phase, 208V, 240V