ELECTRIC STATIONARY KETTLES
ELECTRICAL CONNECTION
: Electrical and ground- ing connections must comply with appli- cable portions of the National Electric Code and/or other local electrical codes.
Disconnect electrical power to the machine and follow Lockout/ Tagout procedures.
1.Open the control box.
2.Using the wiring diagram for reference, connect electric supply to terminal block.
ELECTRICAL SPECIFICATIONS
|
|
| Amperage per Line |
| Minimum |
| ||||
MODEL | kW | PHASE |
|
|
| Circuit Ampacity | ||||
|
|
| 208V | 240V | 480V | 208V |
| 240V |
| 480V |
K20EL/ELT | 12 | 1 | 57.7 | – | – | 75 |
| – |
| – |
|
| 3 | 33.3 | – | 14.4 | 45 |
| – |
| 20 |
|
|
|
|
|
|
|
|
|
|
|
| 16 | 1 | – | 66.7 | – | – |
| 85 |
| – |
|
|
|
|
|
|
|
|
|
|
|
|
| 3 | – | 38.5 | – | – |
| 50 |
| – |
|
|
|
|
|
|
|
|
|
|
|
K40EL/ELT | 18 | 3 | 50.0 | 43.3 | 21.7 | 65 |
| 55 |
| 30 |
K60EL/ELT |
|
| ||||||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
K40EL/ELT | 24 | 3 | 66.6 | 57.7 | 28.9 | 85 |
| 75 |
| 40 |
K60EL/ELT |
|
| ||||||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
K60EL/ELT | 33 | 3 | 91.6 | 79.4 | 39.7 | 115 |
| 100 |
| 50 |
|
|
|
|
|
|
|
|
|
|
|
— 7 —