Snorkel Oven and/or Electric Ignition Oven with KX Thermostat

Snorkel Oven and/or Electric Ignition Oven with KX Thermostat

1.Place the instrument sensor or thermometer in the center of the oven cavity and close the door.

2.Turn fan switch on. Set temperature dial to 300°F. Allow oven to cycle at least five times (approximately 15 minutes). If the temperature is more than 15°F different from the dial setting, calibrate as follows.

A.Pull the dial straight off. Turn the calibration screw (Diagram #10) clockwise to decrease temperature or counterclockwise to increase temperature (1/4 turn equals approximately 35°F).

B.Replace dial and increase temperature 50°F. Allow oven to cycle at least three times and recheck the temperature.

C.If the temperature is more than 15°F different from the dial setting, the thermostat may need to be replaced.

– 17 –

Page 17
Image 17
Vulcan-Hart ML-044962, ML-044937, ML-044936, ML-044969, 44963 Snorkel Oven and/or Electric Ignition Oven with KX Thermostat