Vulcan-Hart ML-136221-00G24 Gas Regulator, Air Shutter Orifice Main Burners, Vent Limiter, Cover

Models: ML-136221-00G24

1 24
Download 24 pages 45.34 Kb
Page 17
Image 17
BURNER CLIP (UNDERNEATH)

BURNER CLIP (UNDERNEATH)

FLASH TUBE

PILOT ASSY

IGNITION PORTS

AIR SHUTTER

ORIFICE

MAIN BURNERS

These photos are for reference – it should not be necessary to remove the griddle top to perform the procedures listed in this manual.

GAS REGULATOR

VENT LIMITER

ADJUSTMENT

 

COVER

REGULATOR INSTALLED IN A HORIZONTAL, UPRIGHT POSITION

The 900RE and AGE series units must have an exterior machine gas regulator installed. The units are shipped with a regulator that has a vent limiter. These regulators must be installed as close as possible to the unit in a horizontal, upright position for optimal performance. They are adjusted by removing the adjustment cover – then by turning the adjustment screw to the right to increase and to the left to decrease. The regulator and griddle can be damaged by gas pressures that exceed 14” W.C. or ½ psig.

- 17 -

Page 17
Image 17
Vulcan-Hart ML-136221-00G24 manual Gas Regulator, Burner Clip Underneath Flash Tube Pilot Assy Ignition Ports, Vent Limiter