BURNER CLIP (UNDERNEATH)
FLASH TUBE
PILOT ASSY
IGNITION PORTS
AIR SHUTTER
ORIFICE
MAIN BURNERS
These photos are for reference – it should not be necessary to remove the griddle top to perform the procedures listed in this manual.
GAS REGULATOR
VENT LIMITER | ADJUSTMENT |
| COVER |
REGULATOR INSTALLED IN A HORIZONTAL, UPRIGHT POSITION
The 900RE and AGE series units must have an exterior machine gas regulator installed. The units are shipped with a regulator that has a vent limiter. These regulators must be installed as close as possible to the unit in a horizontal, upright position for optimal performance. They are adjusted by removing the adjustment cover – then by turning the adjustment screw to the right to increase and to the left to decrease. The regulator and griddle can be damaged by gas pressures that exceed 14” W.C. or ½ psig.
- 17 -