SHUTDOWN OF GRIDDLE

1.Turn thermostats to the OFF position to cut off burners.

2.The pilots will remain lit and monitored by the safety valve as long as the main gas supply is on.

EXTENDED SHUTDOWN

1.Shut off the main gas supply valve.

2.Apply a heavy coat of vegetable oil over the griddle plate to inhibit rust.

MAINTENANCE

The griddle and its parts are hot. Use care when operating, cleaning or servicing the griddle.

LUBRICATION

There are no parts on this griddle that require lubrication.

VENT

Daily, when the griddle is cool, check the flue and clear any obstructions.

SERVICE AND PARTS INFORMATION

Contact the Service Agency in your area to obtain service and parts information. For a complete listing of Service and Parts depots refer to or www.vulcanhart.com.

When calling for service, the following information should be available from the appliance identification plate: Model Number, Serial Number and Gas Type.

- 13 -