INSTALLATION CODES AND STANDARDS

INSTALLATION CLEARANCES

 

 

COMBUSTIBLE CONSTRUCTION

NON-COMBUSTIBLE CONSTRUCTION

Back:

6”

0”

Sides:

6”

0”

INSTALLATION CODES AND STANDARDS

 

The griddle must be installed in accordance with:

In the United States of America:

1.State and local codes.

2.National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained from The American Gas Association Accredited Standards Committee Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 1 Batterymarch Park Quincy, MA 02169-7471

NOTE: In the Commonwealth of Massachusetts

All gas appliances vented through a ventilation hood or exhaust system equipped with a damper or with a power means of exhaust shall comply with 248 CMR.

3.NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

In Canada:

1.Local codes.

2.CAN/CSA-B149.1 Natural Gas Installation (latest edition)

3.CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3

GRIDDLES MOUNTED ON STANDS WITH CASTERS

 

Griddles mounted on stands with casters must use a

 

flexible connector (not supplied) that complies with the

 

Standard for Connectors for Movable Gas Appliances

 

ANSI Z21.69•CSA6.16, and a quick-disconnect device

 

that complies with Gas Fuel, ANSI Z21.3•CSA6.9. In

 

addition, adequate means must be provided to limit

 

movement of the appliance without depending on the

 

connector and the quick-disconnect device (or its

 

associated piping) to limit appliance movement. Attach

 

the restraining device at the rear of the griddle as

 

shown in Fig. 1.

Fig. 1

If disconnection of the restraint is necessary, turn off the gas supply before disconnecting. Reconnect the restraint prior to turning the gas supply on and returning the griddle to its installation position.

Casters are only supplied on a griddle stand. If the griddle is moved for any reason the griddle should be re-leveled (see LEVELING in this manual).

- 4 -