VPX SERIES STEAMERS - REMOVAL AND REPLACEMENT OF PARTS
4.Reverse procedure to install replacement component and check steamer for proper operation.
NOTE: If replacing temperature control, see
"TEMPERATURE CONTROL CALIBRATION - ADJUSTMENT FOR ELEVATION" in "SERVICE PROCEDURES AND ADJUSTMENTS".
TIMER
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.
1.Remove right side panel as outlined under
"COVERS AND PANELS".
2.Disconnect lead wires to timer.
3.Loosen two set screws on dial and pull timer knob from shaft.
4.Remove nut from timer shaft and remove timer.
5.Reverse procedure to install.
STANDBY THERMOSTAT
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.
1.Remove right side panel as outlined under
"COVERS AND PANELS".
2.Pull insulation back to expose standby thermostat and disconnect lead wires.
3.Grasp thermostat body and push up to slide holding tabs out from mounting bracket.
4.Apply a small amount of "thermal transfer compound" to the mating surface (disk side) of the replacement thermostat.
A.Spread the compound completely and evenly over the surface of the thermostat.
5.Reverse procedure from step 3 to install and check steamer for proper operation.
HIGH LIMIT THERMOSTAT
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.
1.Remove right side panel as outlined under
"COVERS AND PANELS".
2.Pull insulation back to expose high limit thermostat and disconnect lead wires.
3.Remove thermostat from heating element assembly.