TROUBLESHOOTING

SYMPTOMS

POSSIBLE CAUSES

REMEDY

 

Oven not connected to

Connect oven to power

 

power source

source

Oven not operating

ON/OFF switch not

Press Power ON/OFF switch

ON

to ON

 

 

No power

Check circuit breaker

 

 

 

 

 

This is normal when unit is

Indicator Lights are lit but

Oven is below 150F.

cold. If unit is above 150F.,

Contact Authorized Service

Cooling Fan(s) are NOT

 

 

Provider.

operating

 

Defective: connection,

Contact Authorized Service

 

 

wiring, fan, thermostat

Provider

Oven compartment IS heating

 

 

and Blower Motor IS NOT

Defective connection or

Contact Authorized Service

operating with Power Switch

wiring to motor

Provider

ON

 

 

 

 

Set Cooking Thermostat to 250F.,

 

 

w ait several minutes and check

 

Defective Cooking

the rear of the oven for heating.

 

Both the Pow er Sw itch and

 

Temperature

 

Cooking Temperature Indicator

 

Thermostat

 

Lights w ill be lit. If oven cavity

 

 

 

 

does not heat, Contact Authorized

Oven compartment IS NOT

 

Service Provider

 

 

heating and Blower Motor IS

 

Turn Holding Temperature knob to

operating with Power Switch

 

Defective Holding

250F. and check for heat at rear

ON

of oven cavity. Both the Pow er

Temperature

 

Sw itch and Cooking Temperature

 

Thermostat

 

Indicator Lights w ill be lit. If the

 

 

 

 

oven cavity does not heat, Contact

 

 

Authorized Service Provider.

 

Defective High-Limit

Contact Authorized Service

 

Thermostat or Heating

 

Element.

Provider

Incorrect oven temperature

Thermostat(s) require

Contact Authorized Service

calibration

Provider

 

21